The Problem
Homeowner's water bill doubled over 3 months. No visible leaks anywhere on the property.
Detection Method
Acoustic correlation from meter to house entry point at the foundation. Found leak at a compression coupling 2m from the house.
Results
1m x 1m excavation at marked spot. Coupling replaced. Yard preserved. Bill returned to normal.